Part Number Hot Search : 
PL0382 MIW5026 ATHLON64 P600A SPC56 757120 SPC56 75024
Product Description
Full Text Search
 

To Download DMS-PS9-CM Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Universal Input
85-264Vac or 110-340Vdc
FEATURES
Up to 80% efficient single, dual, and tripleoutput model Individual, fully-isolated outputs: 3000Vac on main 4000V double-isolation on auxiliaries Available with +5V, +12V, and +24V outputs Low noise: 40mVp-pk on main, 8mVp-pk on auxiliaries; Ideal for sensitive instrumentation Universal input: 85-264Vac @ 47-63Hz or 110-340Vdc Choice of 5, 10, or 16W models for minimal system power-consumption Standby power consumption as low as 0.6W Short-circuit protection on all outputs; OVP on main output Built-in ac mains fuse & `Power On' indicator 5W models operate up to 5 LED-display DPM's Vibration-resistant, chassis-mount modular packages EMC compliant; UL/CSA recognized Low cost!
C
(R)
US E156931
Murata Power Solution's DMS-PS-CM Series of high-efficiency, chassis mount AC/DC power supplies feature low noise (40mV on main, 8mV on auxiliaries), fully-isolated +24, +12V, and +5V outputs, making them perfect for powering today's complex instrumentation. A high-current main output is isolated from the AC line by 3000Vac. In dual- and triple-output models, the low-current auxiliary outputs are isolated from the main output by 1000Vdc, and from each other by 2000Vdc, effectively providing double isolation from the AC line! This unprecedented isolation eliminates ground loop problems in complex, multiple-instrument applications. Full-load efficiencies of up to 80% and output-power ratings of 5, 10 or 16 Watts, combine to ensure minimal ac power consumption. For intermittent use or low-power applications, the 5-Watt model's no-load quiescent consumption with a nominal 120Vac input is a mere 0.6 Watts---that's nearly seven times less than a standard 4W
night light! These low cost, high-efficiency power supplies can significantly reduce long-term electricity costs in low (<5Watts) to medium (<16Watts) power applications. All DMS-PSX-CM power supplies feature universal inputs of 85-264Vac 50/60Hz, built-in line fuses, and on-board `Power On' LED indicators. At full rated load, hold-up time is typically 20ms at 120Vac, and 80ms at 230Vac. All outputs provide indefinite short-circuit protection and, for added reliability, the main high-current output also includes overvoltage protection. A rugged, vibration-proof, chassis mount package incorporates large, shock-resistant terminal blocks for all I/O connections. Multiple outputs, low noise, low cost, high efficiency, double isolation, and rugged construction combine to make DMS-PSXCM Series AC/DC power supplies the ideal choice for powering today's sensitive instrumentation, and any electronic device that requires a reliable dc voltage!
DC/DC ** Converter + - DC/DC ** Converter AC(L) TB4 F1 1A/250V AC/DC Converter + - AC(N) + + - + + -
LDO Regulator
IN OUT GND
TB3 + + V3 (Auxilliary) -
LDO Regulator
IN OUT GND
TB2 + + V2 (Auxilliary) -
85-264V 50/60Hz or or 110-340Vdc 110-340Vdc
*
FG Drive Circuitry + +
TB1 + V1 (Main) -
*Not used on single-output models **Used only on dual and triple-output models
For full details go to www.murata-ps.com/rohs
Figure 1. Simplified Schematic Figure 1. DMS-PS-CM Series Simplified Schematic www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MPM_DMS-PS-CM.B02 Page 1 of 8
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Performance/Functional Specifications
Typical at TA = +25C and VIN = 85-264V @47-63Hz AC Input Input Voltage Range, All models Input Current (115V/230V, typ.): 5-Watt Models 10-Watt Models 16-Watt Models Inrush Current (All models, typical peak): @115Vac @230Vac Isolation (Min.): Output V1 to AC Input Outputs V2 & V3 to AC Input AC Input to Frame Ground Output V1 to Frame Ground Outputs V2 & V3 to Frame Ground Outputs V2 & V3 to Output V1 Output V2 to Output V3 Frame Ground Leakage Current (Max.): @115Vac @230Vac Switching Frequency (Typical): V1 (5W and 10W models) V1 (16W models) V2 & V3 (All models) Line Fuse (Built-in) IEC60127-2, sheet 3 specification (slow-blow) AC Mains Terminal Block (TB4): Wire Size & Type Insulation Strip Length Screw Tightening Torque Rated Voltage 250V (VDE 0110-V. Group 3) EMI (All models) Class B Safety Approvals DC Outputs Line Regulation (All outputs) Load Regulation: V1 (All models) V2 & V3 (All models) Output Accuracy (Max.): V1 (All models) V2 & V3 (All models) Hold-Up Time (47-63Hz): @115Vac @230Vac Noise & Ripple (All models, 20MHz bandwidth): V1 V2 & V3 Transient Response DC Outputs (continued) Efficiency (Typ.@ 120Vac, full load): Single Output Models Dual Output Models Triple Output Models
85-264V @47-63Hz 0.15A/0.07A 0.3A/0.13A 0.33A/0.16A 14.1A 32.5A 3000Vac 3000Vac + 1000Vdc 1500Vac 500Vac 500Vac + 1000Vdc 1000Vdc 2000Vdc 0.5mA 3.5mA 75kHz 83kHz 100kHz 1A/250Vac, 5 x 20mm, meeting for time lag fuses
75% 73% 71%
DC-Output Terminal Blocks (TB1, TB2, TB3): Wire Size &Type 16-20AWG (1.5 to 0.5mm2), solid or stranded Insulation Strip Length 0.25 inches (6.4mm) Screw Tightening Torque 3.6 pound-inches (0.4Nm) Short Circuit Protection (All outputs) Overvoltage Protection V1 (max.) Environmental Operating Temperature -25 to +70C @ 50% rated power Storage Temperature Cooling Notes) Humidity (Non-condensing) Physical Dimensions Weight: 5 Watt Models 10 Watt Models 16 Watt Models Case Materials: Outer Case DC/DC Modules AC/DC Modules 0 to 85% Foldback, self-recovering 134% x Vout
0 to +50C @ full rated power; (see Figure 3) -40 to +85C Free air convection with derating (see Figure 3 and Technical
See Mechanical Specifications 5.8 ounces (165 grams) 6.9 ounces (195 grams) 7.9 ounces (223 grams) ABS, UL94 5VA Phenolic, UL94 V-0 Plastic, UL94 V-1
14-20AWG (2.5 to 0.5mm2), solid or stranded 0.25 inches (6.4mm) 4.4 pound-inches (0.5Nm) 630V (VDE 0110-V. Group 2); Meets CISPR Pub. 22 & FCC Pending
All models will also operate from a regulated and filtered 110 to 340Vdc input. Unless otherwise specified, load regulation is measured with the output under test undergoing a load change of 100% to 50% at nominal line input and, when applicable, with all other outputs operating at 50% of rated load. Transient response is defined as the output returning to within its specified tolerance in 10ms or less, following a 90% load change.
0.1% (max) 2% 0.2% (max) 2.0% 2.5% 20mSec. typ. 80mSec. typ. See Noise & Ripple graphs 40mVp-pk (typ.) 8mVp-pk (typ.) See Transient Response graphs
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-PS-CM.B02 Page 2 of 8
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Ordering Information and Selection Guide
MPS Part No. DMS-PS1-CM DMS-PS2-CM DMS-PS3-CM DMS-PS4-CM DMS-PS5-CM DMS-PS6-CM DMS-PS7-CM DMS-PS8-CM DMS-PS9-CM DMS-PS10-CM
Efficiency typical @120V/60Hz
Rated Power 5 Watts 5 Watts 5 Watts 10 Watts 10 Watts 10 Watts 16 Watts 16 Watts 16 Watts 16 Watts
Efficiency 75% 73% 71% 80% 75% 73% 82% 76% 74% 82%
V1 Output 5Vdc/1A 5Vdc/0.65A 5Vdc/0.35A 24Vdc/0.45A 24Vdc/0.35A 24Vdc/0.30A 24Vdc/0.70A 24Vdc/0.60A 24Vdc/0.55A 12Vdc/1.35A
V2 Output -- 4.85Vdc/0.2A 4.85Vdc/0.2A -- 4.85Vdc/0.2A 4.85Vdc/0.2A -- 4.85Vdc/0.2A 4.85Vdc/0.2A --
V3 Output -- -- 4.85Vdc/0.2A -- -- 4.85Vdc/0.2A -- -- 4.85Vdc/0.2A --
TECHNICAL NOTES
IMPORTANT! To ensure safe and reliable operation, DMS-PS-CM power supplies must be installed and serviced by qualified personnel. Contact Murata Power Solutions if there is any doubt regarding their installation and/or operation. Please read all of the following technical and application notes BEFORE installing or making connections to DMS-PS-CM power supplies.
Warnings (Marking)
Caution, unit may become hot in normal operation, thereby creating a potential burn hazard. Disconnect ac mains and then allow unit to cool before servicing. Reference document: IEC 417, No. 5041. Dangerous, potentially lethal voltages are present during normal operation. Disconnect ac mains before servicing. Reference document: IEC 417, No. 5036.
3. Fuse Replacement: If any dc-output drops to zero volts, and no fault conditions exist within the external load circuitry or the ac mains, F1 may have failed. F1 is located on the circuit (etch) side of the pc-board. Fuse replacement is performed by first de-energizing and then disconnecting the ac mains from TB4. Next, disconnect all load wiring from TB1, TB2, and TB3. Lastly, remove the four screws that secure the pc-board to the plastic case. After making sure that the new fuse is securely attached to its mounting clips, re-assemble the unit using all four screws. Reconnect all input and output wiring and re-apply ac power. If the unit still does not operate properly, and the ac supply at TB4 is measured to be within its specified operating range, the power supply is defective and must be replaced. Except for F1, DMS-PS-CM supplies contain no other user-serviceable components. 4. Wire Gauges and Fusing: All wiring connected to the DMS-PS-CM's terminal blocks must meet the requirements specified in the Functional Specifications section. All ac supply and load wiring must be rated for the voltages and currents they will conduct and must comply with any code or application-mandated requirements pertaining to the user's specific installation. Applications subject to vibration should include adequate strain reliefs on both input and output wiring. Install the strain reliefs within 2-3 inches (5-7.5cm) of the terminal blocks. It is recommended that all wiring be rated for 600V and 105C operation (UL1015 type, for example). Also, wire insulation must be stripped to within 10% of the dimensions shown in Figure 2. All wires must be inserted into their respective terminal blocks such that the screw terminal does not pinch their insulation. No more than two wires should be connected to any single terminal on TB1 through TB4. If two wires are attached to a single terminal, be sure to use only two 20AWG (0.5mm2) wires on TB1, TB2, and TB3, and only two 18 or 20AWG (0.75 or 0.5mm2) wires on TB4.
Caution, refer to accompanying documents for more information. Reference document: ISO 3864, No. B.3.1.
1. Shock Hazard: DMS-PS-CM Series power supplies feature touch-proof terminals blocks and fully-isolated plastic construction, thereby greatly reducing the risk of electrical shock. However, these are mains-powered devices whose operation is derived from hazardous and potentially lethal voltages. All service and installation must be performed by qualified personnel, with the ac supply voltage de-energized. Before making connections to any of the unit's terminal blocks, use a digital voltmeter to verify that the ac supply is de-energized (off). 2. AC Supply Fuse (F1): All DMS-PS-CM Series power supplies are equipped with a built-in 1A/250V time-lag fuse. Replacement fuses must be of the same type and rating; please refer to the Functional Specifications section of this datasheet for more information. F1 is conservatively rated in order to reduce nuisance tripping which might occur during power-up or output overload conditions. However, F1 is primarily intended to provide protection in the event of catastrophic failure in the DMS-PS-CM's ac/dc converter.
0.25" (6.4mm)
Figure 2. Insulation Strip Length
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
www.murata-ps.com
MPM_DMS-PS-CM.B02 Page 3 of 8
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
The ac-mains circuit supplying power to DMS-PS-CM supplies must be fused according to the current rating of the wire gauge used, in accordance with applicable regulatory codes. The built-in 1ampere line fuse (F1) only protects the module itself from destructive over currents. 5. AC Mains Connections (TB4): To ensure EMI-compliant operation, all three ac-supply inputs must be properly connected to TB4. Never operate any DMSPS-CM power supply without a ground connection to TB4's `FG' terminal. On 120Vac 50/60Hz mains, connect the black or "hot" lead to `AC(L)', the white or "neutral" lead to `AC(N)', and the supply ground (earth) to `FG' (Frame Ground). On 220V 50/60Hz ac mains with line and neutral conductor-designations, connect the line to AC(L), the neutral to AC(N), and the ground to `FG'. 6. Connector Torque Ratings: It is extremely important to tighten all input and output terminal blocks securely. TB4's screw terminals must be torqued to 4.4 pound-inches (0.5Nm). TB1, TB2, and TB3 must be torqued to 3.6 poundinches (0.4Nm). Proper tightening will minimize losses and ensure safe, reliable operation. 7. `Power On' LED: The Power On LED indicates that the unit has ac-power applied and its V1 dc-output is operational. However, the power-on LED's illumination does not imply nor guarantee that the unit's dc-outputs are within their specified accuracy. 8. Output Adjustment: The main output, V1, on all 5, 10, and 16W models is adjustable by approximately -10% to +15%. V1's adjustment potentiometer is accessed via a small hole located next to the Power-On LED. While not recommended, field adjustment of single-output models can be performed within the tolerance window noted above. However, keep in mind that the unit's maximum output power capability must not be exceeded. For example, increasing V1's output voltage by 10% produces a corresponding 10% reduction in V1's maximum output current. On dual-and triple-output units, V1 is factory calibrated with all outputs simultaneously loaded to 100% of their rated current. On all dual- and triple output models, adjusting V1 under any condition other than those just noted (i.e., all outputs loaded to their full rated current) will
2.0% / C 100
adversely affect the operation and stability of auxiliary outputs V2 and V3. On these models, V1 must be adjusted to within 2 % of its nominal value (+5.0V, +12.0V, or +24.0V, depending on model). 9. Temperature Derating (See Figure 3): All DMS-PS-CM supplies are specified to operate at their full rated power over the temp range of 0C to +50C in still air (convection cooling) without any thermal derating. For operation over +50C in still air, derate the output power linearly by 2.5% per C down to 50% rated power at +70C. To operate the units at full rated power between +50C and +70C, a minimum forced-airflow of 100 LFM is required. For operation below 0C, derate the output power linearly by 2.0% per C down to 50% rated power at -25C. Unless forced air with the velocity noted above is employed, DMS-PS-CM supplies should never be mounted upside down (terminal blocks facing down). Also, always provide sufficient clearances in order to ensure adequate airflow around the supply. 10. V1 Peak Capabilities: DMS-PS-CM power supplies have a maximum continuous output-current rating that's specified in the Ordering and Selection Guide. In addition, each model's V1 output can intermittently supply 120% of its continuous rated current for short periods of time if the duty cycle is less than 10%. Peak current ratings do not apply to the auxiliary outputs V2 or V3. 11. Isolated Outputs: Unlike the majority of competitive ac/dc power supplies, all dual- and triple-output DMS-PS-CM power supplies feature fully-isolated outputs. This is an important feature when, for reasons of high common mode voltages, an instrument's input circuit must be isolated from the system ground. All V1 outputs are isolated from the ac mains by a minimum of 3000Vac, while auxiliary outputs V2 and V3 are isolated from one another by 2000Vdc, and fromV1 by 1000Vdc. The low noise, double-isolated auxiliaries are ideal for powering sensitive instrumentation that requires low ac leakage-currents. All ac/dc and dc/dc power components utilized in the construction of DMSPS-CM power supplies are 100% hi-pot tested during their manufacturing processes. In addition, after final assembly by MPS, all models are subjected to an additional hi-pot testing consisting of 1000Vac sequentially applied between the ac mains input and each output, and between each output and all other outputs.
75 Output Power (%)
2.5% / C
50
70C
25
0 -25 -10 0 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Figure 3. Temperature Derating
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-PS-CM.B02 Page 4 of 8
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Application Information
1. Chassis Mounting Considerations: In order to minimize self-heating, DMS-PS-CM power supplies should always be mounted in either a vertical or horizontal position. Avoid mounting units upside-down or in close proximity to other heat-generating devices. Also, be sure to use the mounting hardware described in Figure 4 below in order to ensure a secure, vibration-resistant installation. 3. Model Selection & Energy Conservation: In order to achieve the lowest possible energy consumption, be sure to determine your application's total current requirements. This is especially true when using DMS-PS-CM supplies to power DATEL's energy-efficient LED and/or LCD display digital panel meters (DPMs) and process monitors. In general, choose a power supply that will accommodate your maximum current consumption plus a 20% margin. Choosing the lowest-wattage model suitable for a given application will provide lower procurement costs and lower long-term operating costs. When calculating total current requirements in installations employing three or more DMS-Series meters, it is acceptable practice to use each meter's typical current consumption rating. However, be sure to consult the relevant product datasheets for all instrumentation comprising your application. For applications where DMS-PS-CM power supplies will be powering only Murata Power Solution's DPM's, a 5-Watt DMS-PS3-CM can power up to four, standard intensity (`-RS' suffix) red-LED DMS-30PC meters: two meters on V1, and one meter each on V2 and V3. The same DMS-PS3-CM could also be used to power over 40 low-power red DMS-30PC meters (`-RL' suffix), or over 800 DMS-30LCD non-backlit meters! Of course, these statements are made without regard to ground-loop problems that may be encountered when powering 800 DPM's from a single power supply.
Screw, Split Lock Washer, Flat Washer Panel/Chassis
Threaded Hole
Screw, Flat Washer
Panel/Chassis Hole Flat Washer, Split Lock Washer, Nut
Figure 4. Chassis Mounting
2. Bipolar Operation (See Figure 5): DMS-PS-CM power supplies' fully isolated outputs allow for the generation of bipolar (positive and negative) supply voltages. Bipolar outputs can be used to power dual-supply operational amplifiers, as well as any other type of instrumentation that requires bipolar supply voltages. However, please keep in mind that when connecting and operating any two outputs in this fashion, each output retains its maximum current rating.
DMS-PS6-CM - V1 + - V2 + - V3 +
Scope Probe Oscilloscope
V1 - +
BW = 20MHz
DMS-PS-CM
Figure 6. Measuring Ripple and Noise
+24V COM
-5V
+5V
Figure 5. Bipolar Connections
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-PS-CM.B02 Page 5 of 8
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Typical Performance Curves
TA = +25C, VIN = 120V @60Hz
Noise and Ripple - 100% Load, 20MHz Bandwidth
DMS-PS3-CM V1 (+5V) DMS-PS6-CM V1 (+24V) DMS-PS9-CM V1 (+24V)
DMS-PS3-CM
V2 (+4.85V)
DMS-PS6-CM
V2 (+4.85V)
DMS-PS9-CM
V2 (+4.85V)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-PS-CM.B02 Page 6 of 8
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Typical Performance Curves
TA = +25C, VIN = 120V @60Hz
Transient Response - 10% to 100% Load Step
DMS-PS3-CM V1 (+5V) DMS-PS6-CM V1 (+24V) DMS-PS9-CM V1 (+24V)
DMS-PS3-CM
V2 (+4.85V)
DMS-PS6-CM
V2 (+4.85V)
DMS-PS9-CM
V2 (+4.85V)
Mechanical Dimensions: Inches (mm) Tolerances: 2 PL DEC 0.02 (0.51), 3 PL DEC 0.010 (0.254)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-PS-CM.B02 Page 7 of 8
DMS-PS-CM Series
Mechanical Specifications
MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: 2 PL DEC 0.02 (0.51) 3 PL DEC 0.010 (0.254)
5 Watt & 10 Watt Models Power On V1 Adjust V1 Power Adjust On 16 Watt Models
High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
Detail
See detail
0.188 (4.8) AC(L) AC(N) FG
(R)
(R)
DMS-PSX-CM AC/DC POWER SUPPLY
TB3
+ V3 - + V2 - + V1 - 2.835 (72.0)
TB2
(R)
TB4 TB1
(R)
1.42 (36.1)
4.625 (117.5) 5.125 (130.2) 1.000 (25.4)
4.165 (105.8)
5W models: 0.77 (19.6) 10W models: 0.87 (22.1) 16W models: 0.93 (23.6)
0.125 (3.2)
USA: Canada: UK: France: Germany: Japan: China: Singapore:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
11/24/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2008 Murata Power Solutions, Inc.
www.murata-ps.com
MPM_DMS-PS-CM.B02 Page 8 of 8


▲Up To Search▲   

 
Price & Availability of DMS-PS9-CM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X